Thiết bị chuyển mạch Switch CISCO SF350-48P-K9-EU 48-port PoE+, 10/100Mbps
Liên hệ
| Hãng sản xuất | CISCO |
| Model | • SF350-48-K9-EU |
| Số cổng kết nối | • 48-port 10/100 |
| Tốc độ LAN | • 10/100Mbps |
| Switch thông minh | • Đúng |
| Mô tả khác | • 48-port 10/100 Managed Switch |
| Bảo hành | • 12 Tháng |
Sản phẩm tương tự
Thiết bị chuyển mạch Switch CISCO C1000-24P-4G-L 24x 10/100/1000 Ethernet PoE+ ports and 195W PoE budget, 4x 1G SFP uplinks
Thiết bị Switch Cisco® Catalyst® 1000 là thiết bị chuyển mạch Layer-2 dành cho các nhóm doanh nghiệp lớn được thiết kế cho các doanh nghiệp nhỏ và văn phòng chi nhánh.
Memory and processor : CPU ARM v7 800 MHz, DRAM 512 MB, Flash memory 256 MB.
Performance: Forwarding bandwidth 1G: 28 Gbps - 10G: 64 Gbps, Switching bandwidth 1G: 56 Gbps - 10G: 128 Gbps, Forwarding rate (64—byte L3 packets) 41.67 Mpps.
Hỗ trợ 2 chuẩn IEEE 802.3af PoE và IEEE 802.3at PoE+ (tối đa 30W/port), The PoE power allocation in the Cisco Catalyst 1000 Series Switches is dynamic and allows flexible power allocation across all ports. With Perpetual PoE, the PoE+ power is maintained during a switch reload.
Tham khảo datasheet về các tính năng của Switch : Performance, Network management, Network security, Redundancy and resiliency, Enhanced QoS, Energy management, Operational simplicity, and Specifications ...
Thiết bị chuyển mạch Switch CISCO SG350-10P-K9 10-Port Gigabit PoE Managed
- 8 10/100/1000 PoE ports with 62W power budget + 2 Combo mini-GBIC ports.
- Performance: Switching capacity 20 Gbps, Forwarding rate 14.88 mpps wire-speed performance.
- Layer 2: Port grouping up to 8 groups, up to 8 ports per group with 16 candidate ports for each (dynamic) 802.3ad link aggregation.
- Layer 3: IPv4 routing Wirespeed routing of IPv4 packets up to 1K static routes and up to 128 IP interfaces, Classless Interdomain Routing (CIDR) Support for CIDR.
- PoE: PoE Power Budget: 62 W, Number of Ports That Support PoE: 8.
- QoS (Quality of Service): Priority levels 8 hardware queues, Scheduling Strict priority and weighted round-robin (WRR) Queue assignment based on DSCP and class of service (802.1p/CoS).
Thiết bị chuyển mạch Switch CISCO SG220-26P-K9-EU 24-port Gigabit PoE+
Bộ chuyển mạch Switch Cisco SG220-26P-K9-EU được thiết kế với 26 Port RJ45 trên đường truyền băng thông tốc độ 10/100/1000Mbps. Cùng với đó là 2 x 10/100/1000 cổng, 2 x combo Gigabit SGP khác biệt với các loại Switch khác bởi nguồn điện PoE+ cung cấp điện năng 382W mang đến giải pháp sử dụng năng lượng hiệu quả.
Thuộc dòng thiết bị chuyển mạch Switch thông minh SG220-26-K9-EU dễ triển khai và cung cấp các tùy chọn quản lý như giao thức quản lý mạng đơn giản (SNMP) và giao diện dòng lệnh (CLI), bên cạnh giao diện trực quan, dựa trên web và tiện ích Cisco FindIT.
Cisco SG220-26P-K9-EU sở hữu giao thức quản lý từ xa CLI, HTTP, TFTP, Telnet, HTTPS, RMON 1, RMON 2, RMON 3, RMON 9,SNMP 1, SNMP 2c, SNMP 3 tạo ra sự tiện lợi cho người dùng.
Thiết bị chuyển mạch Switch Cisco SG220-26P-K9-EU
Thiết bị này cũng được sản xuất theo các tiêu chuẩn IEEE 802.1D, IEEE 802.1Q, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z, IEEE 802.1p, IEEE 802.1, IEEE 802.1w, IEEE 802.1x,IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad (LACP), IEEE 802.3az3az3az đảm bảo sự ổn định và tính bảo mật an toàn cao.
- Quản lý đơn giản và linh hoạt với các giao thức mạng đơn giản SNMP, CLI
- Cấp nguồn qua Ethernet Plus với công suất 30W mỗi cổng
- Mức độ bảo mật và thông minh hơn với danh sách truy cập ACL, QoS
- Dễ dàng cấu hình và triển khai
- Khả năng quản lý mạng linh hoạt khi sử dụng SNMP, giao diện dòng lệnh CLI
- Hỗ trợ cho các ứng dụng bảo mật mạng như IEEE 802.1X và bảo mật cổng có thể giới hạn chặt chẽ quyền truy cập vào các phân đoạn cụ thể trong mạng của bạn.
- Mạng LAN ảo của khách (VLAN) cho phép bạn cung cấp kết nối Internet cho người dùng không có việc làm trong khi cô lập các dịch vụ kinh doanh quan trọng từ lưu lượng khách.
- ACL mở rộng có thể hạn chế các phần nhạy cảm của mạng từ người dùng trái phép và bảo vệ chống lại các cuộc tấn công mạng.
- Các cơ chế bảo mật như kiểm soát bão unicast broadcast / multicast / unicast và bộ bảo vệ dữ liệu giao thức cầu (BPDU) có thể bảo vệ mạng khỏi các cấu hình không hợp lệ hoặc mục đích độc hại.
- Bảo vệ các phiên quản lý bằng RADIUS, TACACS + và hỗ trợ xác thực cơ sở dữ liệu cục bộ cũng như truyền thông quản lý an toàn qua SSL, SSH và SNMPv3.
Thông số kỹ thuật SG220-26P-K9-EU chính hãng
Hãng: Cisco
Mã sản phẩm: SG220-26P-K9-EU
Loại: Lắp Rack – 1U
Loại phụ mạng Ethernet tốc độ cao
Cổng kết nối: 24 x 10/100/1000 + 2 x combo Gigabit SFP
Hiệu suất Hiệu suất chuyển tiếp (kích thước gói 64 byte): 38,69 Mpps
Dung lượng chuyển đổi: 52 Gb / giây
Jumbo Frame: Hỗ trợ 9216 byte
Phương pháp xác thực: RADIUS, TACACS +
RAM: 128 MB
Kích thước bảng địa chỉ MAC: 8192 mục nhập
Giao thức quản lý từ xa: CLI, HTTP, TFTP, Telnet, HTTPS, RMON 1, RMON 2, RMON 3, RMON 9,SNMP 1, SNMP 2c, SNMP 3
Kích thước: Chiều rộng 17,3 in x Độ sâu 7,9 in x Chiều cao 1,7 in
Trong lượng: 6,19 lbs
Thiết bị chuyển mạch Switch CISCO SG350X-24P-K9 24-port Gigabit (16-port PoE+/60W)
- Support 20x 10/100/1000 PoE+ ports.
- Support 4x100M/1G/2.5G PoE+ ports (4 support 60W PoE).
- Support 4x10G ports (2x 10GBase-T/SFP+ combo + 2x SFP+).
- Support 375W PoE power budget.
- Switching capacity and forwarding rate: 95.23Mpps; 128Gbps.
- Flash: 256MB.
- CPU: 1.3-GHz and 800-MHz (dual-core) ARM.
- CPU memory: 512MB.
- Dimensions (W x H x D): 440 x 44 x 350 mm.
Thiết bị chuyển mạch Switch CISCO CBS110-24PP-EU 24-port GE, Partial PoE, 2x1G SFP Shared
24 Port Gbps (gồm 12-ports PoE công xuất tổng 100W) + 2 SFP (combo with 2 Gigabit Ethernet).
Performance: Switch capacity 48 Gbps, Capacity in millions of packets per second (mpps) (64-byte packets) 35.7 mpps.
HOL(Head of line) blocking prevention, QoS: priority levels 4 hardware queues, scheduling priority queuing and weighted round-robin (WRR), class of service 802.1p priority based.
Thiết bị chuyển mạch Switch CISCO CBS350-16FP-2G-EU 16-port GE, Full PoE, 2x1G SFP
| Hiệu suất | |
| Dung lượng tính bằng Hàng triệu gói mỗi giây (mpps) (gói 64 byte) | 26,78 |
| Công suất chuyển đổi tính bằng Gigabit trên giây (Gbps) | 36 |
| Chuyển mạch lớp 2 | Giao thức Spanning Tree |
| Nhóm cổng / tổng hợp liên kết | |
| - Lên đến 8 nhóm | |
| - Lên đến 8 cổng cho mỗi nhóm với 16 cổng ứng cử viên cho mỗi VLAN tổng hợp liên kết 802.3ad (động) | |
| -Hỗ trợ đồng thời lên đến 4.094 VLAN | |
| -Dựa trêncổngvà 802.1Q các VLAN dựa trên thẻ;VLAN dựa trên MAC;VLAN dựa trên giao thức;VLAN dựa trên mạng con IP | |
| -Quản lýVLAN-Quản lý VLAN | |
| riêng tư với cổng cộng đồng, riêng lẻ và | |
| riêng tư -Private VLAN Edge (PVE), còn được gọi là cổng được bảo vệ, với nhiều liên kết lên | |
| #NAME? | |
| -Chỉ định VLAN động qua máy chủ RADIUS cùng với xác thực máy khách 802.1x | |
| #NAME? | |
| VoiceVLAN Multiticast | |
| TV VLAN | |
| Dịch VLAN | |
| Q-in-Q | |
| Chọn lọc Q-in-Q | |
| Giao thức đăng ký VLAN chung (GVRP) / Giao thức đăng ký thuộc tính chung (GARP) | |
| Phát hiện liên kết một chiều (UDLD) | |
| Giao thức cấu hình máy chủ động (DHCP) Chuyển tiếp tại | |
| Giao thức quản lý nhóm Internetlớp 2( IGMP) phiên bản 1, 2 và 3 theo dõi | |
| IGMP Querier | |
| Head-of-Line (HOL) chặn | |
| Loopback DetectioN | |
| Lớp 3 | Định tuyến IPv4 - Định tuyến |
| tốc độ cao của các gói IPv4 -Lên | |
| tới 990 tuyến tĩnh và lên đến 128 giao diện IP | |
| Định tuyến IPv6Giao diện | |
| lớp 3 | |
| -Cấu hìnhgiao diệnlớp 3 trên cổng vật lý, Tổng hợp liên kết (LAG), giao diện VLAN hoặc giao diện | |
| lặp lại Định tuyến liên miền không lớp (CIDR) | |
| Định tuyến dựa trên chính sách (PBR) | |
| DHCP Server | |
| DHCP relay tại chuyển tiếp | |
| Giao thức dữ liệu người dùng (UDP)lớp 3 | |
| Bảo vệ | Giao thức Secure Shell (SSH) |
| Lớp cổng bảo mật (SSL) | |
| IEEE 802.1X (Vai trò trình xác thực) Xác thực | |
| dựa trên web | |
| Đơn vị dữ liệu giao thức cầu STP (BPDU) Bảo vệ | |
| STP Root Guard | |
| STPBảo vệlặp lại | |
| DHCP snooping | |
| IP Source Guard (IPSG) | |
| Kiểm tra ARP động ( DAI) | |
| IP / MAC / Cảng Binding (IPMB) | |
| bảo vệ Core Technology (SCT) | |
| bảo mật nhạy cảm dữ liệu (SSD) | |
| hệ thống đáng tin cậy | |
| VLAN Private | |
| layer 2 ly Private VLAN Edge (PVE) với cộng đồng VLAN | |
| Cảng an ninh | |
| RADIUS / TACACS + | |
| RADIUS chiếm | |
| bão kiểm soát | |
| phòng chống DoS | |
| Nhiều cấp độ đặc quyền của người dùng trong CLI | |
| ACLs Hỗ trợ lên đến 1.024 quy tắc | |
| Sự quản lý | Giao diện người dùng web |
| SNMP | |
| Giám sát từ xa (RMON) | |
| IPv4 và IPv6 ngăn xếp kép | |
| Nâng cấp chương trình cơ sở | |
| Cổng phản chiếu | |
| VLAN phản chiếu | |
| DHCP (tùy chọn 12, 66, 67, 82, 129 và 150 | |
| ) | |
| Tự động cấu hình bản sao an toàn (SCP) với tải xuống tệp Bản sao bảo mật (SCP) | |
| Tệp cấu hình có thể chỉnh sửa văn bản | |
| Smartports | |
| Auto Smartports | |
| Textview CLI | |
| Dịch vụ đám mây | |
| Nhúng đầu dò cho Cisco Business Dashboard Tác nhân | |
| Mạng Cisco Plug and Play (PnP) Bản | |
| địa hóa | |
| Biểu ngữ đăng nhập | |
| Quản lý khác | |
| Sự tiêu thụ năng lượng | |
| Mức tiêu thụ điện của hệ thống | 110V = 18,63W |
| 220V = 18,37W | |
| Mức tiêu thụ nguồn (với PoE) | N / A |
| Tản nhiệt (BTU / giờ) | 64.46 |
| Phần cứng | |
| Tổng số cổng hệ thống | 18 Gigabit Ethernet |
| Cổng RJ-45 | 16 Gigabit Ethernet |
| Cổng kết hợp (RJ 45 + Có thể cắm hệ số dạng nhỏ [SFP]) | 2 SFP |
| Cổng điều khiển | Cổng bảng điều khiển mini USB Type-B / RJ45 Chuẩn của Cisco |
| khe cắm USB | Khe cắm USB Loại A trên bảng điều khiển phía trước của công tắc để quản lý tệp và hình ảnh dễ dàng |
| nút | Nút reset |
| Loại cáp | Cặp xoắn không được che chắn (UTP) Loại 5e trở lên cho 1000BASE-T |
| Đèn LED | Hệ thống, Liên kết / Hành động, PoE, Tốc độ |
| Tốc biến | 256 MB |
| CPU | 800 MHz ARM |
| Bộ đệm gói | 1,5 MB |
| Thuộc về môi trường | |
| Kích thước đơn vị (W x H x D) | 268 x 272 x 44 mm (10,56 x 10,69 x 1,73 in) |
| Đơn vị trọng lượng | 1,78 kg (3,92 lb) |
| Quyền lực | 100-240V 50-60 Hz, nội bộ, phổ quát |
| Chứng nhận | 23 ° đến 122 ° F (-5 ° đến 50 ° C) |
| Nhiệt độ bảo quản | -13 ° đến 158 ° F (-25 ° đến 70 ° C) |
| Độ ẩm hoạt động | 10% đến 90%, tương đối, không ngưng tụ |
| Độ ẩm bảo quản | 10% đến 90%, tương đối, không ngưng tụ |
| Tiếng ồn âm thanh và thời gian trung bình giữa sự cố (MTBF) | |
| QUẠT | Không quạt |
| Tiếng ồn âm thanh | N / A |
| MTBF ở 25 ° C (giờ) | 2.165.105 |
Thiết bị chuyển mạch Switch CISCO SG350-28MP-K9-EU 24-port PoE+
| Model | SG350-28MP-K9-EU |
| Performance | |
| Switching capacity and forwarding rate | Capacity in Millions of Packets per Second (mpps) (64-byte packets): 41.66 |
| All switches are wire speed and nonblocking | Switching Capacity in Gigabits per Second (Gbps): 56 |
| USB slot | For file-management purposes |
| Total System Ports | 28 Gigabit Ethernet |
| RJ-45 Ports | 24 Gigabit Ethernet |
| Combo Ports (RJ‑45 + SFP) | 2 SFP slots, 2 Gigabit Ethernet combo |
| Jumbo frames | Frame sizes up to 9K (9216) bytes supported on 10/100 and Gigabit interfaces |
| MAC table | Up to 16K (16384) MAC addresses |
| Layer 2 Switching | |
| Spanning Tree Protocol | Standard 802.1d Spanning Tree support Fast convergence using 802.1w (Rapid Spanning Tree [RSTP]), enabled by default 8 instances are supported Multiple Spanning Tree instances using 802.1s (MSTP) |
| Port grouping | Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP): Up to 8 groups, Up to 8 ports per group with 16 candidate ports for each (dynamic) 802.3ad link aggregation |
| VLAN | Support for up to 4096 VLANs simultaneously Port-based and 802.1Q tag-based VLANs MAC-based VLAN Management VLAN Private VLAN Edge (PVE), also known as protected ports, with multiple uplinks Guest VLAN Unauthenticated VLAN Dynamic VLAN assignment via RADIUS server along with 802.1x client authentication CPE VLAN |
| Voice VLAN | Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoS Auto voice capabilities deliver networkwide zero-touch deployment of voice endpoints and call control devices |
| Multicast TV VLAN | Multicast TV VLAN allows the single multicast VLAN to be shared in the network while subscribers remain in separate VLANs (also known as MVR) |
| Q-in-Q VLAN | VLANs transparently cross a service provider network while isolating traffic among customers |
| Generic VLAN Registration Protocol (GVRP)/Generic Attribute Registration Protocol (GARP) | Protocols for automatically propagating and configuring VLANs in a bridged domain |
| Unidirectional Link Detection (UDLD) | UDLD monitors physical connection to detect unidirectional links caused by incorrect wiring or cable/port faults to prevent forwarding loops and blackholing of traffic in switched networks |
| Dynamic Host Configuration Protocol (DHCP) Relay at Layer 2 | Relay of DHCP traffic to DHCP server in different VLAN; works with DHCP Option 82 |
| Internet Group Management Protocol (IGMP) versions 1, 2, and 3 snooping | IGMP limits bandwidth-intensive multicast traffic to only the requesters; supports 1K multicast groups (source-specific multicasting is also supported) |
| IGMP Querier | IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router |
| Head-Of-Line (HOL) blocking | HOL blocking prevention |
| Loopback Detection | Loopback detection provides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STP |
| Jumbo frames | Up to 9K (9216) bytes |
| Layer 3 | |
| IPv4 routing | Wirespeed routing of IPv4 packets Up to 1K static routes and up to 128 IP interfaces |
| IPv6 routing | Wirespeed routing of IPv6 packets |
| Classless Interdomain Routing (CIDR) | Support for CIDR |
| Layer 3 Interface | Configuration of Layer 3 interface on physical port, LAG, VLAN interface, or loopback interface |
| DHCP relay at Layer 3 | Relay of DHCP traffic across IP domains |
| User Datagram Protocol (UDP) relay | Relay of broadcast information across Layer 3 domains for application discovery or relaying of bootP/DHCP packets |
| DHCP Server | Switch functions as an IPv4 DHCP server serving IP addresses for multiple DHCP pools/scopes Support for DHCP options |
| Security | |
| Secure Shell (SSH) Protocol | SSH is a secure replacement for Telnet traffic. SCP also uses SSH. SSH v1 and v2 are supported |
| Secure Sockets Layer (SSL) | SSL support: Encrypts all HTTPS traffic, allowing highly secure access to the browser-based management GUI in the switch |
| IEEE 802.1X (Authenticator role) | 802.1X: RADIUS authentication and accounting, MD5 hash; guest VLAN; unauthenticated VLAN, single/multiple host mode and single/multiple sessions Supports time-based 802.1X Dynamic VLAN assignment |
| Web-based authentication | Web based authentication provides network admission control through web browser to any host devices and operating systems |
| STP Bridge Protocol Data Unit (BPDU) Guard | A security mechanism to protect the network from invalid configurations. A port enabled for BPDU Guard is shut down if a BPDU message is received on that port |
| STP Root Guard | This prevents edge devices not in the network administrator’s control from becoming Spanning Tree Protocol root nodes |
| DHCP snooping | Filters out DHCP messages with unregistered IP addresses and/or from unexpected or untrusted interfaces. This prevents rogue devices from behaving as DHCP Servers |
| IP Source Guard (IPSG) | When IP Source Guard is enabled at a port, the switch filters out IP packets received from the port if the source IP addresses of the packets have not been statically configured or dynamically learned from DHCP snooping. This prevents IP Address Spoofing |
| Dynamic ARP Inspection (DAI) | The switch discards ARP packets from a port if there are no static or dynamic IP/MAC bindings or if there is a discrepancy between the source or destination addresses in the ARP packet. This prevents man-in-the-middle attacks |
| IP/MAC/Port Binding (IPMB) | The preceding features (DHCP Snooping, IP Source Guard, and Dynamic ARP Inspection) work together to prevent DOS attacks in the network, thereby increasing network availability |
| Secure Core Technology (SCT) | Makes sure that the switch will receive and process management and protocol traffic no matter how much traffic is received |
| Secure Sensitive Data (SSD) | A mechanism to manage sensitive data (such as passwords, keys, and so on) securely on the switch, populating this data to other devices, and secure autoconfig. Access to view the sensitive data as plaintext or encrypted is provided according to the user-configured access level and the access method of the user |
| Layer 2 isolation Private VLAN Edge (PVE) with community VLAN | PVE (also known as protected ports) provides Layer 2 isolation between devices in the same VLAN, supports multiple uplinks |
| Port security | The ability to lock source MAC addresses to ports and limits the number of learned MAC addresses |
| RADIUS/TACACS+ | Supports RADIUS and TACACS authentication. Switch functions as a client |
| Storm control | Broadcast, multicast, and unknown unicast |
| RADIUS accounting | The RADIUS accounting functions allow data to be sent at the start and end of services, indicating the amount of resources (such as time, packets, bytes, and so on) used during the session |
| DoS prevention | Denial-Of-Service (DOS) attack prevention |
| ACLs | Support for up to 512 rules Drop or rate limit based on source and destination MAC, VLAN ID or IP address, protocol, port, Differentiated Services Code Point (DSCP)/IP precedence, TCP/UDP source and destination ports, 802.1p priority, Ethernet type, Internet Control Message Protocol (ICMP) packets, IGMP packets, TCP flag, time-based ACLs supported |
| Quality of Service | |
| Priority levels | 8 hardware queues |
| Scheduling | Strict priority and Weighted Round-Robin (WRR)Queue assignment based on DSCP and class of service (802.1p/CoS) |
| Class of service | Port based; 802.1p VLAN priority based; IPv4/v6 IP precedence/Type of Service (ToS)/DSCP based; Differentiated Services (DiffServ); classification and remarking ACLs, trusted QoS |
| Rate limiting | Ingress policer; egress shaping and rate control; per VLAN, per port, and flow based |
| Power over Ethernet (PoE) | |
| 802.3af PoE, 802.3at PoE+, and 60W PoE power are delivered over any of the RJ-45 ports within the listed power budgets | Switches support 802.3at PoE+, 802.3af, 60W PoE, and Cisco prestandard (older) PoE. Maximum power of 60W to any 10/100 or Gigabit Ethernet port for PoE+ supported devices and 15.4W for PoE supported devices, until the PoE budget for the switch is reached. The total power available for PoE per switch is as follows: Power Dedicated to PoE: 382W Number of Ports That Support PoE: 24 |
| PoE powered device and PoE passthrough | In addition to AC power, compact switch models can work as PoE powered devices and be powered by PoE switches connected to the uplink ports. The switch can also pass through the power to downstream PoE end devices if required Maximum of 60W can be drawn per uplink port if the peer PoE switch supports 60W PoE. When multiple uplink ports are connected to PoE switches, the power drawn from these ports is combined When AC power is connected and functioning properly, it will have priority over the PoE powered device function. The PoE powered device function will then act as a backup power source to the AC power. The PoE powered device function will be the primary power source for the switch if AC power is not connected |
| Power Option | AC power |
| Available PoE Power (W) | 62W |
| Can Switch Be Powered with Uplinks | Yes |
| Environmental | |
| Dimensions | 440 x 44 x 257 mm |
| Weight | 3.37 kg |
Thiết bị chuyển mạch Switch CISCO CBS350-24FP-4G-EU 24-port GE, Full PoE, 4x1G SFP
| Hiệu suất | |
| Dung lượng tính bằng Hàng triệu gói mỗi giây (mpps) (gói 64 byte) | 41,66 |
| Công suất chuyển đổi tính bằng Gigabit trên giây (Gbps) | 56 |
| Chuyển mạch lớp 2 | Giao thức Spanning Tree |
| Nhóm cổng / tổng hợp liên kết | |
| - Lên đến 8 nhóm | |
| - Lên đến 8 cổng cho mỗi nhóm với 16 cổng ứng cử viên cho mỗi VLAN tổng hợp liên kết 802.3ad (động) | |
| -Hỗ trợ đồng thời lên đến 4.094 VLAN | |
| -Dựa trêncổngvà 802.1Q các VLAN dựa trên thẻ;VLAN dựa trên MAC;VLAN dựa trên giao thức;VLAN dựa trên mạng con IP | |
| -Quản lýVLAN-Quản lý VLAN | |
| riêng tư với cổng cộng đồng, riêng lẻ và | |
| riêng tư -Private VLAN Edge (PVE), còn được gọi là cổng được bảo vệ, với nhiều liên kết lên | |
| #NAME? | |
| -Chỉ định VLAN động qua máy chủ RADIUS cùng với xác thực máy khách 802.1x | |
| #NAME? | |
| VoiceVLAN Multiticast | |
| TV VLAN | |
| Dịch VLAN | |
| Q-in-Q | |
| Chọn lọc Q-in-Q | |
| Giao thức đăng ký VLAN chung (GVRP) / Giao thức đăng ký thuộc tính chung (GARP) | |
| Phát hiện liên kết một chiều (UDLD) | |
| Giao thức cấu hình máy chủ động (DHCP) Chuyển tiếp tại | |
| Giao thức quản lý nhóm Internetlớp 2( IGMP) phiên bản 1, 2 và 3 theo dõi | |
| IGMP Querier | |
| Head-of-Line (HOL) chặn | |
| Loopback DetectioN | |
| Lớp 3 | Định tuyến IPv4 - Định tuyến |
| tốc độ cao của các gói IPv4 -Lên | |
| tới 990 tuyến tĩnh và lên đến 128 giao diện IP | |
| Định tuyến IPv6Giao diện | |
| lớp 3 | |
| -Cấu hìnhgiao diệnlớp 3 trên cổng vật lý, Tổng hợp liên kết (LAG), giao diện VLAN hoặc giao diện | |
| lặp lại Định tuyến liên miền không lớp (CIDR) | |
| Định tuyến dựa trên chính sách (PBR) | |
| DHCP Server | |
| DHCP relay tại chuyển tiếp | |
| Giao thức dữ liệu người dùng (UDP)lớp 3 | |
| Bảo vệ | Giao thức Secure Shell (SSH) |
| Lớp cổng bảo mật (SSL) | |
| IEEE 802.1X (Vai trò trình xác thực) Xác thực | |
| dựa trên web | |
| Đơn vị dữ liệu giao thức cầu STP (BPDU) Bảo vệ | |
| STP Root Guard | |
| STPBảo vệlặp lại | |
| DHCP snooping | |
| IP Source Guard (IPSG) | |
| Kiểm tra ARP động ( DAI) | |
| IP / MAC / Cảng Binding (IPMB) | |
| bảo vệ Core Technology (SCT) | |
| bảo mật nhạy cảm dữ liệu (SSD) | |
| hệ thống đáng tin cậy | |
| VLAN Private | |
| layer 2 ly Private VLAN Edge (PVE) với cộng đồng VLAN | |
| Cảng an ninh | |
| RADIUS / TACACS + | |
| RADIUS chiếm | |
| bão kiểm soát | |
| phòng chống DoS | |
| Nhiều cấp độ đặc quyền của người dùng trong CLI | |
| ACLs Hỗ trợ lên đến 1.024 quy tắc | |
| Sự quản lý | Giao diện người dùng web |
| SNMP | |
| Giám sát từ xa (RMON) | |
| IPv4 và IPv6 ngăn xếp kép | |
| Nâng cấp chương trình cơ sở | |
| Cổng phản chiếu | |
| VLAN phản chiếu | |
| DHCP (tùy chọn 12, 66, 67, 82, 129 và 150 | |
| ) | |
| Tự động cấu hình bản sao an toàn (SCP) với tải xuống tệp Bản sao bảo mật (SCP) | |
| Tệp cấu hình có thể chỉnh sửa văn bản | |
| Smartports | |
| Auto Smartports | |
| Textview CLI | |
| Dịch vụ đám mây | |
| Nhúng đầu dò cho Cisco Business Dashboard Tác nhân | |
| Mạng Cisco Plug and Play (PnP) Bản | |
| địa hóa | |
| Biểu ngữ đăng nhập | |
| Quản lý khác | |
| Sự tiêu thụ năng lượng | |
| Mức tiêu thụ điện của hệ thống | 110V = 25,91W |
| 220V = 25,63W | |
| Mức tiêu thụ nguồn (với PoE) | N / A |
| Tản nhiệt (BTU / giờ) | 89,13 |
| Phần cứng | |
| Tổng số cổng hệ thống | 28 Gigabit Ethernet |
| Cổng RJ-45 | 24 Gigabit Ethernet |
| Cổng kết hợp (RJ 45 + Có thể cắm hệ số dạng nhỏ [SFP]) | 4 SFP |
| Cổng điều khiển | Cổng bảng điều khiển mini USB Type-B / RJ45 Chuẩn của Cisco |
| khe cắm USB | Khe cắm USB Loại A trên bảng điều khiển phía trước của công tắc để quản lý tệp và hình ảnh dễ dàng |
| nút | Nút reset |
| Loại cáp | Cặp xoắn không được che chắn (UTP) Loại 5e trở lên cho 1000BASE-T |
| Đèn LED | Hệ thống, Liên kết / Hành động, PoE, Tốc độ |
| Tốc biến | 256 MB |
| CPU | 800 MHz ARM |
| Bộ đệm gói | 1,5 MB |
| Thuộc về môi trường | |
| Kích thước đơn vị (W x H x D) | 445 x 240 x 44 mm (17,5 x 9,45 x 1,73 in) |
| Đơn vị trọng lượng | 2,63 kg (5,80 lb) |
| Quyền lực | 100-240V 50-60 Hz, nội bộ, phổ quát |
| Chứng nhận | 23 ° đến 122 ° F (-5 ° đến 50 ° C) |
| Nhiệt độ bảo quản | -13 ° đến 158 ° F (-25 ° đến 70 ° C) |
| Độ ẩm hoạt động | 10% đến 90%, tương đối, không ngưng tụ |
| Độ ẩm bảo quản | 10% đến 90%, tương đối, không ngưng tụ |
| Tiếng ồn âm thanh và thời gian trung bình giữa sự cố (MTBF) | |
| QUẠT | Không quạt |
| Tiếng ồn âm thanh | N / A |
| MTBF ở 25 ° C (giờ) | 2.026.793 |